2437 Tempe Knoll Dr, North Vancouver
PID 006-673-104, lot 224, plan 20292 · City of North Vancouver records, September 19, 2026.
You can build
4 units
also called a fourplexBecause your lot is larger than 3,014 sq ft (280 m²) and the City's plan marks it Low Rise Neighbourhood 1.
Buildings may cover40%
Ground that soaks up rain35%
The orange block is the footprint the zone allows, split into one part per unit. It is one way to fit them. The square has the same area as your lot; your lot's real shape will differ.
What you can build
- 5,341 sq ft
- Floor space
- 40% of the lot
- Footprint on the ground
- 3 storeys
- Height
- 2 spaces
- Parking to provide
- 9 ft 10 in
- Keep clear at the front
- 4 ft 11 in
- Keep clear at the back
- 3 ft 11 in
- Keep clear at each side
- 35% of the lot
- Ground that must soak up rain
- Yes
- Laneway home or coach house
- 2 permits
- Permits
496 m²
2,514 sq ft (234 m²)
3 m
1.5 m
1.2 m
2,199 sq ft (204 m²)
it is one of the 4 units this zone already allows
Development permit, Building permit, unless the work is exempt
Your lot
- 6,284 sq ft
- Lot size
- Tempe
- Neighbourhood
584 m²
Ground Oriented zone (GO) · Low Rise Neighbourhood 1 · City of North Vancouver records, September 19, 2026. Confirm with the city before you spend money on a design.
2437 Tempe Knoll Dr on the map
How 2437 Tempe Knoll Dr compares
- At 6,284 sq ft, this lot is larger than 80% of the 75 other lots the City of North Vancouver records on Tempe Knoll Dr; the middle lot there is 6,086 sq ft.
- Every other lot on Tempe Knoll Dr is in the same zone, GO.
- Its 4 units is the commonest count on Tempe Knoll Dr: 75 of the 75 other lots may hold the same number.
- Across Tempe, the middle lot is 6,040 sq ft; this one is larger than that.
The full breakdown for 2437 Tempe Knoll Dr
Your lot
- Zone: Ground Oriented (GO)
- Land use category: Low Rise Neighbourhood 1
- Lot area: 6,284 sq ft (584 m²)
- Neighbourhood: Tempe
- PID 006-673-104, lot 224, plan 20292
What the zoning allows on this lot
- Floor space: up to 0.85 times the lot area, which is 5,341 sq ft (496 m²) on this lot. Floor space is the total area of every floor of every building on the lot, added together.
- Lot coverage: 40% of the lot, or 2,514 sq ft (234 m²), for 3 or 4 units. That is the share of the lot buildings may sit on, seen from above.
- Permeable area: 35% of the lot, or 2,199 sq ft (204 m²), for 3 or 4 units. That share must let rain soak into the ground.
- Landscaped area: 20% of the lot, or 1,257 sq ft (117 m²), for 3 or 4 units. That share must be planted, with soil, trees and shrubs.
- Distance from property lines: at least 9 ft 10 in (3 m) from the front, 4 ft 11 in (1.5 m) from the back and 3 ft 11 in (1.2 m) from each side. On a corner lot, 9 ft 10 in (3 m) from the side street, or 0.2 times the lot width if that is less.
- Height: up to 3 storeys. Any part of a building within 16 ft 5 in (5 m) of the rear lot line can be at most 23 ft (7 m) tall. From the lowest floor to the highest ceiling above it can be at most 32 ft 10 in (10 m).
- Parking: at least 0.5 spaces for each unit.
- Every unit must have at least 538 sq ft (50 m²) of floor space inside.
- Every unit must be reachable from the street by a lit path at least 3 ft 3 in (1 m) wide.
- No side of a building can be longer than 68 ft 11 in (21 m).
- Two buildings with units on the same lot must be at least 23 ft (7 m) apart.
- A lot with 3 or more units needs an enclosed space for garbage, organics and recycling.
A laneway home or coach house
- Yes. A separate unit at the back of the lot is one of the units this zone already allows, so it counts towards the lot's number of units rather than being an extra.
- It has to stand at least 23 ft (7 m) from the building at the front, because two buildings with units on one lot must be that far apart.
- Within 16 ft 5 in (5 m) of the rear lot line it can be at most 23 ft (7 m) tall, lower than the 3 storeys allowed further into the lot.
- It shares the lot's floor space, lot coverage and parking figures with the building at the front, rather than adding to them.
- The City's separate coach house permit route is for properties outside this zone.
- From City of North Vancouver, Coach House permit page, read on 2026-09-20.
Sources
- Lot, zone and land use information: City of North Vancouver, downloaded on September 19, 2026. Lot, zoning and overlay information comes from the City of North Vancouver's public mapping service. The City makes no guarantee about the accuracy or completeness of that information. Check anything that matters with the City before you spend money on it.
- Zone rules: Zoning Bylaw, 1995, No. 6700, Amendment Bylaw, 2025, No. 9137, Part 5B, sections 573 to 583, read on 2026-09-18. https://www.cnv.org/-/media/City-of-North-Vancouver/Documents/Housing/Zoning-Bylaw-1995-No-6700-Amendment-Bylaw-2025-No-9137-City-Initiated-Amendment-Related-to-Provincia.pdf
Questions about 2437 Tempe Knoll Dr
How many units can I build at 2437 Tempe Knoll Dr?
Up to 4 units, because your lot is larger than 3,014 sq ft (280 m²) and the City's plan marks it Low Rise Neighbourhood 1. The count comes from Zoning Bylaw, 1995, No. 6700, Amendment Bylaw, 2025, No. 9137, Part 5B, sections 573 to 583.
What zone is 2437 Tempe Knoll Dr in?
Ground Oriented (GO). The City's zone for low-density housing, from a single house up to a small multiplex of 3 to 6 units. It replaced most of the City's single-family and duplex zoning in December 2025. Separately, the city's land use plan marks it Low Rise Neighbourhood 1. The city's records place it in Tempe.
How big is the lot at 2437 Tempe Knoll Dr?
6,284 sq ft (584 m²), from the City of North Vancouver's own outline of the parcel.
How much floor space can I build at 2437 Tempe Knoll Dr?
Up to 0.85 times the lot area, which is 5,341 sq ft (496 m²) on this lot. Floor space is the total area of every floor of every building on the lot, added together.
How tall can I build at 2437 Tempe Knoll Dr?
Up to 3 storeys. Any part of a building within 16 ft 5 in (5 m) of the rear lot line can be at most 23 ft (7 m) tall. From the lowest floor to the highest ceiling above it can be at most 32 ft 10 in (10 m).
Can I build a laneway home or coach house at 2437 Tempe Knoll Dr?
Yes. A separate unit at the back of the lot is one of the units this zone already allows, so it counts towards the lot's number of units rather than being an extra. It has to stand at least 23 ft (7 m) from the building at the front, because two buildings with units on one lot must be that far apart. Within 16 ft 5 in (5 m) of the rear lot line it can be at most 23 ft (7 m) tall, lower than the 3 storeys allowed further into the lot. It shares the lot's floor space, lot coverage and parking figures with the building at the front, rather than adding to them. The City's separate coach house permit route is for properties outside this zone.
Where do these figures come from, and will the city approve my project?
Lot outline, address, area, zone and land use category: the City of North Vancouver's public map, downloaded on September 19, 2026. Zone rules: Zoning Bylaw, 1995, No. 6700, Amendment Bylaw, 2025, No. 9137, Part 5B, sections 573 to 583, read on 2026-09-18. This page shows what the zoning bylaw allows on paper. A real project also needs a building permit, the city reviews each design against more rules than the ones shown here, and the lot may carry limits the city's map does not show. Confirm the rules with the city's planning staff before you pay for a design.
Other lots on Tempe Knoll Dr
- 2436 Tempe Knoll Dr Zone GO · 6,351 sq ft · 4 units
- 2441 Tempe Knoll Dr Zone GO · 6,045 sq ft · 4 units
- 2446 Tempe Knoll Dr Zone GO · 6,086 sq ft · 4 units
- 2427 Tempe Knoll Dr Zone GO · 6,285 sq ft · 4 units
- 2447 Tempe Knoll Dr Zone GO · 6,046 sq ft · 4 units
- 2426 Tempe Knoll Dr Zone GO · 6,416 sq ft · 4 units
- 2421 Tempe Knoll Dr Zone GO · 6,246 sq ft · 4 units
- 2466 Tempe Knoll Dr Zone GO · 6,202 sq ft · 4 units
Lots nearby
- 2411 Wilding Way Zone GO · 7,609 sq ft · 4 units · 144 ft
- 2467 Tempe Knoll Dr Zone GO · 6,045 sq ft · 4 units · 170 ft
- 2477 Tempe Knoll Dr Zone GO · 6,045 sq ft · 4 units · 225 ft
- 2420 Wilding Way Zone GO · 6,046 sq ft · 4 units · 242 ft
- 2416 Wilding Way Zone GO · 6,043 sq ft · 4 units · 244 ft
- 2430 Wilding Way Zone GO · 6,045 sq ft · 4 units · 252 ft
- 2412 Wilding Way Zone GO · 6,046 sq ft · 4 units · 258 ft
- 2476 Tempe Knoll Dr Zone GO · 6,069 sq ft · 4 units · 270 ft
More about building in North Vancouver (City)
Look up another address
6,781 lots, from city records. Pick one to open its page.
Published by RealDream
Planning to build or renovate on your lot?
We build and renovate homes in North Vancouver and West Vancouver. Bring your lot's report to a free consultation and we will talk through what fits your budget.








